INVASIVE MONITORING OF CARDIAC OUTPUT BY PULSE WAVE TRANSIT TIME AFTER AORTOCORONARY BYPASS ON THE BEATING HEART
https://doi.org/10.21292/2078-5658-2016-13-5-4-10
Abstract
Goal of the study: to evaluate the accuracy of invasive measurement of cardiac output (CO) by pulse wave transit time (PWTT) (esCCO, Japan) compared to transpulmonary thermodilution (TPTD) (PiCCO2 , Germany) after aortocoronary bypass (ACB) without cardiopulmonary bypass (ACB without CPB). Methods. 21 patients with ACB without CPB were enrolled into the study. During early post-operative period CO was simultaneously registered at eight stages basing on PWTT (COPWTT) and TPTD (COTPTD). Statistic analysis included evaluation of congruence of CO absolute values and capability to follow-up changes in CO. Results. In accordance with Bland-Altman analysis the average difference between two methods made 0.3 l/min. with consistency limits of ± 2.1 l/min. and percent error of 40%. Polar chart analysis showed the angular difference of 2.6°, radial consistency limits ± 53.3° and polar concordance of 69%. Conclusion: Lower repeatability of CO measurement by PWTT and insufficient capability to follow the changes in CO after ACB without CPB don not allow recommending this method in its invasive variant for routine practice as an alternative to thermodilution methods.
About the Authors
A. A. SmetkinRussian Federation
Candidate of Medical Sciences, Associate Professor of Anesthesiology and Intensive Care Department
Ayyaz Hussain
Russian Federation
Candidate of Medical Sciences, Assistant at Anesthesiology and Intensive Care Department
E. V. Fot
Russian Federation
Candidate of Medical Sciences, Assistant at Anesthesiology and Intensive Care Department
V. I. Zakharov
Russian Federation
Post Graduate Student of Anesthesiology and Intensive Care Department
N. N. Isotova
Russian Federation
Internship Doctor of Anesthesiology and Intensive Care Department
A. S. Yudina
Russian Federation
Resident Physician of Anesthesiology and Intensive Care Department
Z. A. Dityateva
Russian Federation
Internship Doctor of Anesthesiology and Intensive Care Department
Ya. V. Gromova
Russian Federation
Resident Physician of Anesthesiology and Intensive Care Department
V. V. Kuzkov
Russian Federation
Doctor of Medical Sciences, Professor of Anesthesiology and Intesive Care Department
M. Yu. Kirov
Russian Federation
Doctor of Medical Sciences, Professor, Head of Anesthesiology and Intesive Care Department
References
1. Volkov P.А., Sevalkin S.А., Churadze B.T. et al. Targeted infusion therapy based on invasive hemodynamic monitoring of esCCO. Anesteziol. i Reanimatol., 2015, no. 4, pp. 19-23. (In Russ.)
2. Smyotkin А.А., Khussein А.F., Zakharov V.I. et al. Minimally invasive monitoring of cardiac output in coronary surgery: current reality and prospective. Sb. tez. 14-go s"ezda Federatsii anesteziologov-reanimatologov RF. [Abst. Book. 14th Conference of Anesthesiologists and Intensive Care Practitioners' Federation]. September 20–22, 2014, pp. 299-300. (In Russ.)
3. Bataille B., Bertuit M., Mora M. et al. Comparison of esCCO and transthoracic echocardiography for non-invasive measurement of cardiac output intensive care. Br. J. Anaesth., 2012, vol. 109, pp. 879-886.
4. Cecelja M., Chowienczyk P. Role of arterial stiffness in cardiovascular disease. JRSM Cardiovasc. Dis., 2012, vol. 1, doi: 10.1258/cvd.2012.012016.
5. Critchley L.A., Critchley J.A. A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques. J. Clin. Monit. Comput., 1999, vol. 15, pp. 85–91.
6. Critchley L.A., Yang X.X., Lee A. Assessment of trending ability of cardiac output monitors by polar plot methodology. J. Cardiothorac. Vasc. Anesth., 2011, vol. 25, pp. 536-546.
7. Fischer M.O., Balaire X., Le Mauff de Kergal C. et al. The diagnostic accuracy of estimated continuous cardiac output compared with transthoracic echocardiography. Can. J. Anaesth., 2014, vol. 61, pp. 19-26.
8. Hadian M., Kim H.K., Severyn D.A., Pinsky M.R. Cross-comparison of cardiac output trending accuracy of LiDCO, PiCCO, FloTrac and pulmonary artery catheters. Crit. Care, 2010, vol. 14, pp. R212.
9. Ishihara H., Sugo Y., Tsutsui M. et al. The ability of a new continuous cardiac output monitor to measure trends in cardiac output following implementation of a patient information calibration and an automated exclusion algorithm. J. Clin. Monit. Comput., 2012, vol. 26, pp. 465-471.
10. Ishihara H., Tsutsui M. Impact of changes in systemic vascular resistance on a novel non-invasive continuous cardiac output measurement system based on pulse wave transit time: a report of two cases. J. Clin. Monit. Comput., 2014, vol. 28, pp. 423-427.
11. Lee A.J., Cohn J.H., Ranasinghe J.S. Cardiac output assessed by invasive and minimally invasive techniques. Anesthesiol. Res. Pract., 2011, vol. 2011, – 475151.
12. Peyton P.J., Chong S.W. Minimally invasive measurement of cardiac output during surgery and critical care: a meta-analysis of accuracy and precision. Anesthesiology, 2010, vol. 113, pp. 1220-1235.
13. Ribezzo S., Spina E., Di Bartolomeo S. et al. Noninvasive techniques for blood pressure measurement are not a reliable alternative to direct measurement: a randomized crossover trial in ICU. Scientific. World J., 2014, vol. 2014, – P. 353628.
14. Sharwood-Smith G., Bruce J., Drummond G. Assessment of pulse transit time to indicate cardiovascular changes during obstetric spinal anaesthesia. Br. J. Anaesth., 2006, vol. 96, pp. 100-105.
15. Sinha A.C., Singh P.M., Grewal N. et al. Comparison between continuous non-invasive estimated cardiac output by pulse wave transit time and thermodilution method. Ann. Card. Anaesth., 2014, vol. 17, pp. 273-277.
16. Strong J.P., Malcom G.T., McMahan C.A. et al. Prevalence and extent of atherosclerosis in adolescents and young adults: implications for prevention from the Pathobiological Determinants of Atherosclerosis in Youth Study. JAMA, 1999, vol. 281, pp. 727-735.
17. Sugo Y., Sakai T., Terao M. et al. The comparison of a novel continuous cardiac output monitor based on pulse wave transit time and echo Doppler during exercise. Conf. Proc. IEEE. Eng. Med. Biol. Soc., 2012, vol. 2012. pp. 236-239.
18. Thiele R.H., Bartels K., Gan T.J. Cardiac output monitoring: a contemporary assessment and review. Crit. Care Med., 2015, vol. 43, pp. 177-185.
19. Wentland A.L., Grist T.M. Wieben O. Review of MRI-based measurements of pulse wave velocity: a biomarker of arterial stiffness. Cardiovasc. Diagn. Ther., 2014, vol. 4, pp. 193-206.
Review
For citations:
Smetkin A.A., Hussain A., Fot E.V., Zakharov V.I., Isotova N.N., Yudina A.S., Dityateva Z.A., Gromova Ya.V., Kuzkov V.V., Kirov M.Yu. INVASIVE MONITORING OF CARDIAC OUTPUT BY PULSE WAVE TRANSIT TIME AFTER AORTOCORONARY BYPASS ON THE BEATING HEART. Messenger of ANESTHESIOLOGY AND RESUSCITATION. 2016;13(5):4-10. (In Russ.) https://doi.org/10.21292/2078-5658-2016-13-5-4-10